Enter your project conditions to calculate the wind pressure and suction values using the logic and lookup data used in the supplied Winda calculation sheet.
Calculate Your Project ↓

Engineering starts with the load.

Wind load changes with location, building dimensions, terrain, building importance, openings and cyclone conditions.

Use the calculator below to obtain a project-specific preliminary wind-load result before system selection.

Project Wind Load Calculator

IS 875 (Part 3) : 2015 · Windows & Façades
Scope: wind pressure on windows, doors, glazing & cladding in the walls of enclosed rectangular buildings (Table 5). Envelope of all wind directions — orientation not required. Roofs, canopies, free-standing walls and non-rectangular forms are outside this tool.
01

Project

02

Opening Condition

Openings as % of wall area (Cl 7.3.2). A large door, loading bay or open floor that can stay open in a storm → choose > 20%.
03

Project Conditions

Vb from IS 875 (Part 3):2015 Annex A, as amended by Amendment No. 2 (2020). Not listed? Choose “Other location”.
Read from the basic wind speed map, Fig. 1 of NBC 2016 Part 6 Sec 1 (referred by IS 875 Amendment No. 2).
Sets k1 (Table 1) and, near the coast, k4 (Cl. 6.3.4).
East & west coast sites within 60 km of the sea.
04

Building Dimensions

m
Up to the roof / parapet top. Below 10 m, k2 at 10 m is used.
m
Plan dimensions — order does not matter; the shorter side is taken as w.
m
05

What's around the building?

Judge the surroundings once everything nearby is built. On a corner, ridge or facing open ground on one side — choose the more exposed option.
Advanced engineering options
Non-cyclonic building0.90
Typical zone: 0.90 (Cl 7.2.1), 1.00 when cyclone-prone. Corner strips always 1.00 (conservative).
Sets topography factor k3 = 1 + C·s.
For a neighbouring building of the same or greater height (Fig 8). Ignore neighbours under one-third of this building's height.
Flat site1.000
m
From the foot of the upwind slope to the crest.
m
Horizontal length of the upwind slope. θ = tan⁻¹(Z/L).
1.00 = at the crest (upper bound, default). Lower values from Fig C.2 / C.3 for sites away from the crest.
Vb—
k1—
k2 at h—
k4—
Vz m/s—
pz kPa—
h/w · l/w—

Every factor is shown with its clause in the result — ready for your structural consultant.

Calculation Result

Wind Load Calculation

Design pressure for window / façade selection to IS 875 (Part 3):2015 — final verification by the project structural / façade engineer.

Design +ve · pressure—kPa—
Design −ve · suction—kPa—
Typical zone −ve—
Corner strip width y—
Design wind speed Vz at h—
Method for headline valuesDynamic · Gust Factor (Cl 10.2)
Static IS 875 Cl 7 · +ve / −ve—
Dynamic Cl 10.2 · +ve / −ve—

Façade zones

Windows inside the corner strips (hatched) take the corner suction. All other windows use the typical-zone values.

Height-wise design pressures (kPa)

Height bandk2Vz m/spd+ve−ve typical−ve corner
Each band is designed at its top height. Use for floor-wise system selection.
Show full calculation (IS 875-3 : 2015)

Design pressure for window / façade selection to IS 875 (Part 3):2015, walls of enclosed rectangular buildings (Table 5, l/w < 4, h ≤ 500 m). Final verification — profile, glass, hardware, anchoring — by the project structural / façade engineer.

Need help selecting the right system?

Share your project conditions and calculated wind-load requirement with the Winda technical team.

Download the Winda catalogue to explore our engineered aluminium window and door systems.